(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
ADA Accessibility Guidelines
Chapter 9
Accessible Transient Lodging
9.0.0 | ACCESSIBLE TRANSIENT LODGING
9.1.1 | HOTELS, MOTELS, INNS, BOARDING HOUSES, DORMITORIES, RESORTS AND OTHER SIMILAR PLACES OF TRANSIENT LODGING | GENERAL
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
9.1.2 | HOTELS, MOTELS, INNS, BOARDING HOUSES, DORMITORIES, RESORTS AND OTHER SIMILAR PLACES OF TRANSIENT LODGING | ACCESSIBLE UNITS, SLEEPING ROOMS, AND SUITES
![]() |
![]() |
| (a) | (b) |
| Fig. 57 Roll-in Shower with Folding Seat |
|
| Number of Rooms | Accessible Rooms | Rooms with Roll-in Showers |
|---|---|---|
| 1 to 25 | 1 | |
| 26 to 50 | 2 | |
| 51 to 75 | 3 | 1 |
| 76 to 100 | 4 | 1 |
| 101 to 150 | 5 | 2 |
| 151 to 200 | 6 | 2 |
| 201 to 300 | 7 | 3 |
| 301 to 400 | 8 | 4 |
| 401 to 500 | 9 | 4 plus one for each additional 100 over 400 |
| 501 to 1000 | 2% of total | |
| 1001 and over | 20 plus 1 for each 100 over 1000 | |
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
9.1.3 | HOTELS, MOTELS, INNS, BOARDING HOUSES, DORMITORIES, RESORTS AND OTHER SIMILAR PLACES OF TRANSIENT LODGING | SLEEPING ACCOMMODATIONS FOR PERSONS WITH HEARING IMPAIRMENTS
| Number of Elements | Accessible Elements |
|---|---|
| 1 to 25 | 1 |
| 26 to 50 | 2 |
| 51 to 75 | 3 |
| 76 to 100 | 4 |
| 101 to 150 | 5 |
| 151 to 200 | 6 |
| 201 to 300 | 7 |
| 301 to 400 | 8 |
| 401 to 500 | 2% of total |
| 1001 and over | 20 plus 1 for each 100 over 1000 |
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
9.1.4 | HOTELS, MOTELS, INNS, BOARDING HOUSES, DORMITORIES, RESORTS AND OTHER SIMILAR PLACES OF TRANSIENT LODGING | CLASSES OF SLEEPING ACCOMMODATIONS
(2) Equivalent Facilitation. For purposes of this section, it shall be deemed equivalent facilitation if the operator of a facility elects to limit construction of accessible rooms to those intended for multiple occupancy, provided that such rooms are made available at the cost of a single-occupancy room to an individual with disabilities who requests a single-occupancy room.
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
9.1.5 | HOTELS, MOTELS, INNS, BOARDING HOUSES, DORMITORIES, RESORTS AND OTHER SIMILAR PLACES OF TRANSIENT LODGING | ALTERATIONS TO ACCESSIBLE UNITS, SLEEPING ROOMS, AND SUITES
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
9.2.1 | REQUIREMENTS FOR ACCESSIBLE UNITS, SLEEPING ROOMS AND SUITES | GENERAL
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
9.2.2 | REQUIREMENTS FOR ACCESSIBLE UNITS, SLEEPING ROOMS AND SUITES | MINIMUM REQUIREMENTS
(2) An accessible route complying with 4.3 shall connect all accessible spaces and elements, including telephones, within the unit, sleeping room, or suite. This is not intended to require an elevator in multi-story units as long as the spaces identified in 9.2.2(6) and (7) are on accessible levels and the accessible sleeping area is suitable for dual occupancy.
(3) Doors and doorways designed to allow passage into and within all sleeping rooms, suites or other covered units shall comply with 4.13.
(4) If fixed or built-in storage facilities such as cabinets, shelves, closets, and drawers are provided in accessible spaces, at least one of each type provided shall contain storage space complying with 4.25. Additional storage may be provided outside of the dimensions required by 4.25.
(5) All controls in accessible units, sleeping rooms, and suites shall comply with 4.27.
(6) Where provided as part of an accessible unit, sleeping room, or suite, the following spaces shall be accessible and shall be on an accessible route:
(b) the dining area.
(c) at least one sleeping area.
(d) patios, terraces, or balconies.
(f) if only half baths are provided, at least one-half bath.
(g) carports, garages or parking spaces.
(8) Sleeping room accommodations for persons with hearing impairments required by 9.1 and complying with 9.3 shall be provided in the accessible sleeping room or suite.
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
9.3.1 | VISUAL ALARMS, NOTIFICATION DEVICES AND TELEPHONES | GENERAL
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
9.3.2 | VISUAL ALARMS, NOTIFICATION DEVICES AND TELEPHONES | EQUIVALENT FACILITATION
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
9.4.0 | OTHER SLEEPING ROOMS AND SUITES
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
9.5.1 | TRANSIENT LODGING IN HOMELESS SHELTERS, HALFWAY HOUSES, TRANSIENT GROUP HOMES, AND OTHER SOCIAL SERVICE ESTABLISHMENTS | NEW CONSTRUCTION
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
9.5.2 | TRANSIENT LODGING IN HOMELESS SHELTERS, HALFWAY HOUSES, TRANSIENT GROUP HOMES, AND OTHER SOCIAL SERVICE ESTABLISHMENTS | ALTERATIONS
(b) Alteration of other areas shall be consistent with the new construction provisions of 9.5.1.
(b) sleeping space for homeless persons as provided in the scoping provisions of 9.1.2 shall include doors to the sleeping area with a minimum dear width of 32 in (815 mm) and maneuvering space around the beds for persons with mobility impairments complying with 9.2.2(1).
(c) at least one toilet room for each gender or one unisex toilet room shall have a minimum clear door width of 32 in (815 mm), minimum turning space complying with 4.2.3, one water closet complying with 4.16. one lavatory complying with 4.19 and the door shall have a privacy latch; and, If provided, at least one tub or shower shall comply with 4.20 or 4.21, respectively.
(d) at least one common area which a person with mobility impairments can approach, enter and exit including a minimum clear door width of 32 in (815 mm).
(e) at least one route connecting elements (a), (b), (c) and (d) which a person with mobility impairments can use including minimum clear width of 36 in (915 mm), passing space complying with 4.3.4. turning space complying with 4.2.3 and changes in levels complying with 4.3.8.
(f) homeless shelters can comply with the provisions of (a)-(e) by providing the above elements on one accessible floor.
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
9.5.3 | TRANSIENT LODGING IN HOMELESS SHELTERS, HALFWAY HOUSES, TRANSIENT GROUP HOMES, AND OTHER SOCIAL SERVICE ESTABLISHMENTS | ACCESSIBLE SLEEPING ACCOMMODATIONS IN NEW CONSTRUCTION
In facilities with multi-bed rooms or spaces, a percentage of the beds equal to the table provided in 9.1.2 shall comply with 9.2.2(1).
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)
As always, please use it to get the justice you deserve.
Sincerely,