(2) Parallel Approach Only. If only a parallel approach is possible, operable parts of controls shall be placed as follows
(b) Reach Depth More Than 10 in (255 mm). Where the reach depth to the operable parts of any control as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion of the automated teller machine or surround is more than 10 in (255 mm), the maximum height above the finished floor or grade shall be as follows:
| Reach Depth | Maximum Height | ||
|---|---|---|---|
| In | Mm | In | Mm |
| 10 | 255 | 54 | 1370 |
| 11 | 280 | 53½ | 1360 |
| 12 | 305 | 53 | 1345 |
| 13 | 330 | 52½ | 1335 |
| 14 | 355 | 51½ | 1310 |
| 15 | 380 | 51 | 1295 |
| 16 | 405 | 50½ | 1285 |
| 17 | 430 | 50 | 1270 |
| 18 | 455 | 49½ | 1255 |
| 19 | 485 | 49 | 1245 |
| 20 | 510 | 48½ | 1230 |
| 21 | 535 | 47½ | 1205 |
| 22 | 560 | 47 | 1195 |
| 23 | 585 | 46½ | 1180 |
| 24 | 610 | 46 | 1170 |
(4) Bins. Where bins are provided for envelopes waste paper, or other purposes, at least one of each type provided shall comply with the applicable reach ranges in paragraph (1), (2), or (3) of this section.
(“ Standards for Accessible Design”, 28 CFR 36 Appendix D)